Clean the entire cabinet of the machine regularly and remove all traces of soap,
etc....
Remove all detergent residue in the soap dispenser with hot water.
Clean the door gasket and remove all detergents and other products.
Shut off the main water, steam, and power connections at the end of each day.
Do not change the setting of the water inlet taps on boiler fed machines once
these have been installed.
It is recommended to leave the door and soap dispenser open after use, to
ventilate the machine.
Check for proper door lock operation on a daily basis.
General maintenance
Maintenance instruction of the machine
The V-belts of the motors should be retightened after two to three months when
rst used. This is necessary because these belts are subject to a one-time
stretching when rst used. If this is not done, the belt starts to slip after a few
months and will break shortly afterwards.
Check the water inlet lters to make sure they are not blocked by calcication.
Check the drain valve for obstructions.
If a machine frequently skips the nal spin, check whether the probe of the out of
balance switch is still in the appropriate position, that is horizontally centered and
vertically 1/3 from the bottom inside the window. (When the drum is empty).
Lubricate the bearings after every 200 hours of operation or replace the automatic
lubricator annually.
Periodical maintenance
Clean AC drive lter:
a. Snap off external plastic cover which contains lter.
b. Remove foam lter from cover.
c. Wash lter with warm water and allow to air dry. Filter can be vacuumed clean.
End of day
WARNING
To reduce the risk of electric shock, disconnect this appliance
from the power supply before attempting any user maintenance.
Turning the controls to the OFF position does not disconnect this
appliance from the power supply.
Before starting wiring or inspection, power must be switched OFF,
check to make sure that the operation panel indicator is off.
Any person who is involved in wiring or inspection shall wait for
at least 10 minutes after the power supply has been switched OFF
and check that there is no residual voltage using a tester or the
like. The capacitor of the inverter or the EMC lter is charged with
a high voltage for some time after power OFF, and it is dangerous.