Alliance Laundry Systems HC18PC2 Washer User Manual


 
Operation
13
F232137
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Display Indications for V-Series – Non-Coin
Display Meaning Display Meaning
F23n Program identification code (ROM)
(this is an example only)
FIL6 Sixth fill (8th of 11 segments)
FIL7 Seventh fill (9th of 11 segments)
HoLd Wait...power has just been turned on FIL8 Eighth fill (10th of 11 segments)
CY Cycle (followed by two-digit number) FIL9 Ninth fill (11th of 11 segments)
tESt/CYC* Test cycle selected CFIL Cold fill
FAr Degrees Fahrenheit bFIL Warm fill (both hot and cold)
CEL Degrees Celsius HFIL Hot fill
HEAt Auxiliary heat enabled AFIL Auxiliary fill (Setup option)
noHt Auxiliary heat disabled Lo Low water level
tFIL Temperature-controlled fill enabled
nEd
Medium water level
ntFL Temperature-controlled fill disabled HI High water level
CooL Automatic cool-down enabled SUP1 Supply 1
noCL Automatic cool-down disabled SUP2 Supply 2
Ag 1 Agitation 1 selected (90% agitation) SUP3 Supply 3
Ag 2 Agitation 2 selected (33% agitation) SUP4 Supply 4
Ag 3 Agitation 3 selected (10% agitation) SUP5 Supply 5 (or Setup option)
Ag 4 Agitation 4 selected (6.7% agitation) SUP6 Supply 6 (supply 1 and 5)
PU
nP
Pump output enabled (future use only) SUP7 Supply 7 (supply 3 and 4)
nP
nP
Pump output disabled (future use only) For Wash speed, forward direction
PrE Prewash segment (1st of 11 segments) rEv Wash speed, reverse direction
UASH Wash segment (2nd of 11 segments) drAI Drain enabled
FIL1 First fill (3rd of 11 segments) nodr Drain disabled
FIL2 Second fill (4th of 11 segments) STOP Stop routine
FIL3 Third fill (5th of 11 segments) SdLY Spin coast delay
FIL4 Fourth fill (6th of 11 segments) dOnE Cycle and stop routine have ended
FIL5 Fifth fill (7th of 11 segments) dOOr Door not properly closed
FULL The computer detects low water level or
higher when none should be present
FILL/STOP* Programmed water level not reached after 30
minutes
tSFL Temperature sensor failure or
temperature out of range
SPIn/tI
nE* Reads “SPIn” for one second, then “tInE”
followed by time for spin
* Display indications separated by a slash (/) represent a flashing display.
Table 5