Alliance Laundry Systems HC18PC2 Washer User Manual


 
Operation
11
F232137
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Display Indications for V-Series – Coin
Display Meaning Display Meaning
FC 5 Program identification code (ROM)
(this is an example only)
HFIL Hot fill
Lo Low water level
HoLd Wait...power has just been turned on
nEd
Medium water level
PAY/(price)* Pay (flashes alternately with start price if
“FLSH” SETUP option is enabled)
HI High water level
SUP0 No supplies
CYXX Cycle (followed by two-digit number) SUP1 Supply 1
tESt/CYC* Test cycle selected SUP2 Supply 2
FAr Degrees Fahrenheit SUP3 Supply 3
CEL Degrees Celsius SUP5 Supply 5 (supply 1 and 2)
HEAt Auxiliary heat enabled SUP6 Supply 6 (supply 2 and 3)
noHt Auxiliary heat disabled drAI/dISt* Distribution (load balancing before extract)
(Variable-speed only)
drAI/For* Drain step (low speed forward in test cycle)
Strt/A
nt*
Start amount – flashes briefly before
showing vend price in SETUP Mode
SPIn/tI
nE* Reads “SPIn” for one second, then “tInE”
followed by time for spin
SdLY Spin coast delay
Con1/deno* Coin 1 value – flashes briefly before
showing value of coin 1 in SETUP Mode
STOP Stop routine
donE Cycle and stop routine have ended
Con2/deno* Coin 2 value – flashes briefly before
showing value of coin 2 in SETUP Mode
HI 1 Low spin in test cycle (Variable-speed only)
HI 2 High spin in test cycle (Variable-speed only)
PrE Prewash segment (1st of 8 segments) bAL/FAIL* Balance routine failed during test cycle
UASH Wash segment (2nd of 8 segments) SHUT/door* Door not properly closed
FIL1 First fill (3rd of 8 segments) CANt/OPEN* Computer cannot unlock door after five
attempts
FIL2 Second fill (4th of 8 segments)
FIL3 Third fill (5th of 8 segments) FILL/STOP* Programmed water level not reached after
30 minutes
FIL4 Fourth fill (6th of 8 segments)
FIL5 Fifth fill (7th of 8 segments) FULL The computer detects low water level or
higher when none should be present
FIL6 Sixth fill (8th of 8 segments)
AFIL Auxiliary fill dFLt Drive fault detected (Variable-speed only)
bFIL Warm fill (both hot and cold) tSFL Temperature sensor failure or temperature
out of range
CFIL Cold fill
bLCH Add bleach (for supply 2 only) bAL? Special factory balance SETUP Mode
1Pr One vend price – all cycles SPC? Special factory Valve Flush Mode
16Pr 16 vend prices – one per cycle SPIN Spin in test cycle (2 speed only)
CHEC/CYC* Test cycle selected (same as tESt/CYC) rEv Reverse wash speed in test cycle
For Wash speed forward in test cycle
FrEE “Free” cycle option
* Display indications separated by a slash (/) represent an alternating display.