Termination of Flame
The flame will go out when power is removed from
ignition control. The ignition control will turn off the
gas valve and enter Standby Mode.
Lockout Mode
When Lockout Mode is entered, the ignition control
will remove power to the gas valve, the igniter will
turn off, the Lockout/Reset Light will turn on, and the
Diagnostic LED will display the appropriate Error
Code.
Lockout Manual Reset
Lockout Mode is cleared by pressing an external reset
switch for three seconds. The ignition control will
clear all error codes and enter Standby Mode. During
Lockout Manual Reset, the Diagnostic LED on the
ignition control flashes red and orange, and the Reset
Light remains on until the ignition control is reset.
After the Reset Light turns off, stop pressing the
switch. Holding the reset for three seconds after
lockout has been cleared will cause a fault and result in
entering Lockout Mode again.
System Tests
The following system tests are performed during
normal operation. System tests are performed at a
minimum of every 24 hours.
Low Voltage Detection
If the voltage between terminals TH and GND on the
control is below 18.75VAC +/- 0.75VAC for more than
3 seconds the ignition control will turn off the gas
valve and will not attempt to spark. The Diagnostic
LED will display Error Code 5. The ignition control
will not enter Lockout Mode if a low voltage condition
is detected, but will enter Standby Mode and wait for
the low voltage condition to be cleared.
If the voltage between terminals TH and GND on the
control rises above 19.75VAC +/- 0.1VAC for at least 3
seconds, the ignition control will then enter Start Up
Mode.
Low Voltage Detection test is disabled during Run
Mode.
Gas Valve
The ignition control verifies that the gas valve is
connected. Failure of this test results in the ignition
control entering Lockout Mode with the Diagnostic
LED displaying Error Code 2.
Flame Probe Tests
Unexpected Presence of Flame
The Unexpected Presence of Flame test is performed
when no flame is expected. Failure of this test results
in the ignition control entering Lockout Mode with the
Diagnostic LED displaying Error Code 3.
Flame Monitoring
During the Flame Monitoring test, the flame is
checked to ensure the gas is being burned when the gas
valve is on. Failure of this test will result in the
ignition control entering Lockout Mode with the
Diagnostic LED displaying Error Code 3.