Alliance Laundry Systems Drying Cabinet Clothes Dryer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
19
70304601
9. Wipe out the cylinder using an all-purpose
cleaner or detergent and water solution. Refer to
Figure 5.
Figure 5
If the tumbler does not meet ANY of the listed
requirements, remove tumbler from use. Refer to
Removing Tumbler from Service section
Required for CE Models Only
Once machine is installed, please be sure to complete
the following items:
Review and verify machine operation with
customer.
Leave all literature and a signed Declaration of
Conformity with customer.
Review machine warranty information with
customer.
Apply warning sticker on front panel of machine,
in language appropriate to country of sale
(included in literature packet).
Installing CE Gas Drying Tumblers
General Information
This information is to be used when installing gas
tumblers in countries, and/or on gases, different than
the machine’s factory configuration. Tumblers are
supplied from the factory for operation on Natural Gas
1000 Btu/cu ft. (8914 kcal/m
3
), or L.P. Gas 2500 Btu/
cu ft. (22,250 kcal/m
3
) in the countries of GB/IE/PT/
ES/IT/GR/LU/CH. To install machines in any other
country, or on any other gas, requires some level of
modification.
Burner orifices, stickers, block-open kits, regulator
springs and other parts needed for conversions are to
be ordered separately.
Models are built in two different configurations:
Regulated Natural Gas – Burner orifice is sized
for Natural Gas, second family, group H (E) at
20 mbar inlet pressure. Regulator/governor is
operational. Gas valve CAN be field-converted to
a non-regulating type.
Unregulated L.P. (Liquefied Petroleum) Gas
Burner orifice is sized for L.P., third family,
group 3+ at 28.37 mbar inlet pressure. Regulator/
governor is blocked open. Gas valve CANNOT
be field-converted to a regulating type.
Serial plates supplied from the factory are configured
for the countries of GB/IE/PT/ES/IT/GR/LU/CH.
These instructions pertain to the situations when the
country of use or gas supply is different than that on
the serial plate.
T452I
T452I
WARNING
To reduce the risk of electric shock, fire,
explosion, serious injury or death:
Disconnect electric power to the
tumbler before servicing.
Close gas shut-off valve to gas tumbler
before servicing.
Close steam valve to steam tumbler
before servicing.
Never start the tumbler with any guards/
panels removed.
Whenever ground wires are removed
during servicing, these ground wires
must be reconnected to ensure that the
tumbler is properly grounded.
W002