Alliance Laundry Systems Dryer Tumblers Clothes Dryer User Manual


 
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Installation/Operation Supplement
70392201 (EN)
14
Position and Level the Tumbler
Figure 1
TMB2110N
NOTE: Shaded areas indicate adjacent structure.
1 13 mm (0.5 in.) recommended between machines for removal or installations.
2 Allow 51-102 mm (2-4 in.) opening at top of machine to aid in removal or installation. A removable trim piece may
be used to conceal the opening; zero clearance allowed for trim.
3 102 mm (4 in.) Maximum Header Thickness
4 305 mm (12 in.) Minimum Clearance
5 610 mm (24 in.) minimum, 914 mm (36 in.) recommended for maintenance purposes.
6 Provision for make-up air: Minimum 709 cm
2
(110 in.
2
) required per tumbler for 25 and 30, 928 cm
2
(144 in.
2
) for
35 and 55 pound models, 1418 cm
2
(220 in.
2
) for T30 models and 1856 cm
2
(288 in.
2
) for T45 models. Location
for reference only. May be anywhere behind tumbler.
6 mm (0.25 in.) recommended for removal or installation purposes, zero clearance allowed.
TMB211
0
N
To reduce the risk of severe injury, clearance of tumbler cabinet from combustible
construction must conform to the minimum clearances.
W056
WARNING
TMB2021N
2
4
5
6
7
3
2
4
3
1
TMB2021N
1
7
25, 30, 35 AND 55 POUND
5
6
T30 AND T45