Alliance Laundry Systems D0582 Clothes Dryer User Manual


 
Page 15
The size of the gas service pipe is dependant upon many variables,
such as tees, lengths, etc. Specific pipe size should be obtained from
the gas supplier. Refer to the Gas Pipe Size Chart in this manual for
general gas pipe size information.
CAUTION
Gas loop piping must be installed as shown in Illustration, to
maintain equal gas pressure for all dryers connected to a single
gas service.
Other gas using appliances should be connected upstream
from the loop.
WARNING
(LIQUIFIED PETROLEUM GASES ONLY)
A Gas Pressure Regulator for Liquified Petroleum Gases is
not furnished on Gas Heated Clothes Dryers. This regulator
is normally furnished by the installer. In accordance with
American Gas Association (AGA) standards, a gas pressure
regulator, when installed indoors, must be equipped with a
vent limiter, or a vent line must be installed from the gas
pressure regulator vent to the outdoors.
GAS PIPING
GAS SERVICE
INSTALLATION
INFORMATION