Alliance Laundry Systems CHM160C Washer User Manual


 
Maintenance
21
F232172
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Figure 17
2. For 80 pound capacity models only, lubricate
bearings and seals each month OR after every
200 hours of operation. Refer to Figure 17.
a. Use a premium-grade lithium-based #2
grease. Never mix two types of grease, such
as petroleum and silicone.
b. Pump the grease gun slowly, permitting only
the following number of strokes:
Bearing grease fitting, 2 strokes
Seal grease fitting, 1 stroke
NOTE: Do not pump the grease gun until grease
comes out of the bearing housing. This can result in
overlubrication, causing damage to bearings and
seals.
3. Remove back panel and check overflow hose and
drain hose for leaks.
4. Unlock the hinged lid and check the supply
dispenser hoses and hose connections.
5. Clean inlet hose filter screens:
a. Turn water off and allow valve to cool, if
necessary.
b. Unscrew inlet hose and remove filter screen.
c. Clean with soapy water and reinstall. Replace
if worn or damaged.
6. Tighten motor mounting bolt locknuts and
bearing bolt locknuts. Check to see that the pin is
in place.
H047I
1 Bearing Grease Fitting
2 Seal Grease Fitting
H047I
1
2