Alliance Laundry Systems 907003062 Clothes Dryer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Operation
11
70421001 (EN)
Figure 5
Dual Digital Timer Control
RQ Control Suffix
1. Select HIGH, MED, LOW or NO HEAT by
turning the temperature knob.
HIGH Temperature 190°F (88°C)
MED Temperature 170°F (77°C)
LOW Temperature 120°F (49°C)
2. Set the HEAT TIME for the number of minutes
(from 0-60) desired.
3. Set the COOL DOWN TIME for the number of
minutes (from 0-15) desired.
4. Select reversing or nonreversing cylinder rotation
setting, if applicable.
5. Press and release START button to start tumble
dryer. Display will show minutes remaining
before end of cycle.
NOTE: One touch drying is available for repetitive
loads. If the START button is pressed while the
machine is in Idle Mode, when the display is dark,
the tumble dryer will repeat the last drying cycle. If
the cycle time is adjusted before the cycle is started,
the time displayed when the start button was
pressed will be used for future cycles.
IMPORTANT: To stop the tumble dryer at any
time during the cycle, OPEN DOOR. If the loading
door or lint panel door is opened during the cycle,
the heating system will shut off and the motor will
stop. To restart the cycle, both doors must be closed
and the START button must be pressed in.
If the load cools to 90° F before cool down time
expires, the control will flash “Lr” (load ready) in the
heat time display. If the door is not opened, the tumble
dryer completes the selected cool down time. If the
door is opened after reaching “Lr” temperature, the
cycle will be terminated.
NOTE: If display shows an error code, refer to
Error Codes section.
6. When the cycle is complete, open door and
remove the laundry. Anti-wrinkle feature will
tumble the load without heat for 30 seconds
every 2 minutes for 1 hour OR until the loading
door is opened.
NOTE: This machine includes an anti-wrinkle/
extended tumble feature. After the drying cycle is
complete, the cylinder will tumble without heat
every few minutes. The intermittent tumbling will
continue for one hour or until the door is opened.
TMB2136N