Alliance Laundry Systems 602004144 Clothes Dryer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Operating Instructions
70400101 (EN)
14
Door Open Mode
In Door Open Mode, the control turns off the heater
and motor when the door is opened during a run cycle.
The timer will continue to count down time and the
IN USE LED is lit.
End of Cycle Mode
In End of Cycle Mode, a cycle is complete and the
IN USE LED is off. The control remains in this mode
until the door is opened or additional vend has been
satisfied
Topoffs
Any time the control receives a coin drop pulse during
a cycle it will add the programmed dry time to the time
currently remaining in the cycle. The maximum cycle
time is 99 minutes, the control will not add time
beyond 99 minutes. The cool down time will not
change.
If the control receives a coin drop pulse during cool
down the IN USE LED will flash briefly to indicate the
coin input, the machine will exit cool down and it will
start heating. The cycle time will be equal to the
programmed dry time
Temperature Selector Switch
For five minutes after the control is powered up, there
is a diagnostic feature that allows the temperature
selector switches to be tested.
When the temperature selector is changed, the new
setting is displayed by flashing the IN USE LED as
follows:
High/Normal: 4 flashes
Medium/PP: 3 flashes
Low/Delicate: 2 flashes
No Heat: 1 flash
NOTE: To change dipswitch settings refer to
Installation Manual.
To Program a Short Test Cycle:
1. Unplug machine power cord.
2. Write down machine control dip switch settings,
then set them all to the off position. Refer to
Figure 6.
3. Plug machine in and start a cycle.
NOTE: With all control dip switches off, the total
cycle time will be 2 minutes long (1 minute of heat
and 1 minute of cool down).
4. Once all testing is complete, unplug machine and
re-set dip switches to their original settings.
5. Plug machine in.
Figure 6
Error Codes
TMB2216N
1 2 3 4 5 6 7 8O
N
1
2345
6
78
Display Definition Corrective Action
AF (Flashing)
Airflow switch opened/closed 5 or more
times in a running cycle.
Check airflow switch. Replace if inoperative.
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumble dryer before servicing.
Close gas shut-off valve to gas tumble dryer before servicing.
Close steam valve to steam tumble dryer before servicing.
Never start the tumble dryer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumble dryer is properly grounded.
W002R1
WARNING