Alliance Laundry Systems 602004144 Clothes Dryer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Operating Instructions
13
70400101 (EN)
Figure 5
Single Drop Control
SD and SX Control Suffixes
1. Select HIGH, MED, LOW or NO HEAT by
turning the temperature knob.
HIGH temperature 190°F (87°C)
MED temperature 160°F (71°C)
LOW temperature 130°F (54°C)
2. Insert the coin(s) in the coin slot.
3. Press START button to start tumble dryer.
IMPORTANT: To stop the tumble dryer at any
time during the cycle, OPEN DOOR. To restart the
tumble dryer, CLOSE door and press START
button.
NOTE: If display show an error code, refer to
Error Codes section.
4. When the cycle is complete, open door and
remove the laundry.
NOTE: This machine includes an extended tumble
feature. Starting 20 minutes after a cycle ends, the
cylinder will tumble for two minutes every hour
without heat, up to 18 hours or until door is
opened.
Preliminary Control Information
Power-Up Mode
When power is applied to the tumble dryer the control
will enter Ready Mode, unless a cycle was in process
prior to a disruption of power. If a power disruption is
less than 5 seconds, with a cycle in process, the control
will enter Run Mode once power is restored and
continue the cycle. If a power disruption is more than
5 seconds, with a cycle in process, the control will
enter Start Mode once power is restored.
If the dry time dipswitch settings have not changed
from the factory default, the IN USE LED will flash
two to five times, depending on model.
Ready Mode
In Ready Mode, the control waits for the vend to be
satisfied before entering Start Mode.
Start Mode
In Start Mode, the vend has been satisfied, but the
Start button has not been pressed. The IN USE LED
will be lit. The timer will not count down until the
Start button is pressed.
Run Mode
In Run Mode, the control is running a cycle. The IN
USE LED is lit.
TMB2120N
25
C