AEG 50265 Washer User Manual


 
Installation and connection instructions
43
Electrical connection
Details of the mains voltage, current
type and required fuses can be
found on the rating plate. The ra-
ting plate is located at the top
above the filling door.
For permanent electrical connection
within the electrical circuit, provi-
sions must be made which allow for electrical disconnection of the ap-
pliance from the mains with a contact opening of at least 3 mm at all
poles. Suitable devices include circuit breakers, fuses (threaded fuses
must be entirely removed from the socket), ground fault circuit inter-
rupters and contactors. Permanent connection may only be carried out
by an authorised electrician.
;
This appliance complies with the following EC directives:
The "Low Voltage Directive" 72/23/EU with changes
The "EMC Directive" 89/336/EU with changes
Water connection
3
The washing machine has safety features which prevent back-contami-
nation of the drinking water and which conform to the national regu-
lations of the water authorities (e.g. for Germany: DVGW guidelines).
This means that additional protective measures in the installation are
not necessary.
Important!
Units for connecting to cold water must not be connected to hot wa-
ter.
Use only new hose sets for the connection.
Permissible water pressure
The water pressure must be at least 1 bar (= 10 N/cm
2
= 0.1 Mpa), max-
imum 10 bar = 100 N/cm
2
= 1 Mpa).
If more than 10 bar: Connect a pressure-reduction valve upstream.
If less than 1 bar: Unscrew the inlet hose on the unit side at the sole-
noid intake valve and remove the flow regulator (to do this, remove
the filter with pointed pliers and take out the rubber washer behind).
Replace the filter.