AEG 16950A3 Washer/Dryer User Manual


 
7. When no more water comes out, un-
screw the pump cover by turning it an-
ti-clockwise and remove the filter. Use
pliers, if necessary. Always keep a rag
nearby to dry up any water spillages
when removing the cover.
Clean the filter under a tap, to remove
any traces of fluff.
8. Remove foreign bodies and fluff from
the filter seat and from the pump im-
peller.
9. Check carefully whether the pump im-
peller rotates (it rotates jerkily). If it
doesn’t rotate, please contact your Serv-
ice Centre.
10. Put the cap back on the emergency
emptying hose and place the latter back
in its seat.
11. Replace the filter into the pump by in-
serting it correctly into the special
guides. Screw the pump cover firmly by
turning it clockwise.
12. Refit the flap and close the pump door.
WARNING!
When the appliance is in use and depending on the programme selected there can be hot
water in the pump.
Never remove the pump cover during a wash cycle, always wait until the appliance has fin-
ished the cycle, and is empty. When refitting the pump cover, ensure it is securely re-tight-
ened so as to stop leaks and young children being able to remove it.
Care and cleaning 27