450412-4 www.amdry.com 23
EE PROM FAULT ### – Error in memory location. The ###
indicates the location of the fault.
Input/Output Board L.E.D. Indicators
Inputs
ESTOP – (RED L.E.D.): This L.E.D. will indicate the status of
the E-STOP. If the E-STOP has been pressed, then the
L.E.D. is on.
GAS_V – (RED L.E.D.): This L.E.D. will indicate the status of
the gas valve. If the gas valve is open (ON), then the L.E.D.
is on.
BRHL – (RED L.E.D.): This L.E.D. will indicate the status of
the burner high limit disk. If the disk is closed (temperature
below 330º F [166º C]), then the L.E.D. is ON.
SAIL – (RED L.E.D.): This L.E.D. will indicate the status of
the sail switch. If the switch is closed, then the L.E.D. is
ON.
EXHL – (RED L.E.D.): This L.E.D. will indicate the status of
the exhaust high limit disk. If the disk is closed
(temperature below 225º F [107º C]), then the L.E.D. is ON.
MAIN – (RED L.E.D.): This L.E.D. will indicate the status of
the main door. If the door is closed, then the L.E.D. is ON.
LINT – (RED L.E.D.): This L.E.D. will indicate the status of
the lint drawer. If the drawer is closed, then the L.E.D. is
ON.
FUSE – (RED L.E.D.): This L.E.D. will indicate the status of
the control voltage.
Outputs
STEAM – (GREEN L.E.D.): This L.E.D. will indicate the status
of the steam injection output. If the request to turn on the
steam injection is made, then the L.E.D. is ON.
_HEAT – (GREEN L.E.D.): This L.E.D. will indicate the status
of the heat output. If the request to turn on the heater is
made, then the L.E.D. is ON.
AIR – (GREEN L.E.D.): This L.E.D. will indicate the status of
the air jet output. If the request to turn on the air jet is made,
then the L.E.D. is ON.
REV – (GREEN L.E.D.): This L.E.D. will indicate the status of
the tumbler reverse direction output. If the request to tumble
the drum in the reverse direction is made, then the L.E.D.
is ON.
FWD – (GREEN L.E.D.): This L.E.D. will indicate the status
of the tumbler forward direction output. If the request to
tumble the drum in the forward direction is made, then the
L.E.D. is ON.
FAN – (GREEN L.E.D.): This L.E.D. will indicate the status of
the fan output. If the request to turn on the fan (blower) is
made, then the L.E.D. is ON.
Data Label ___________________________
Contacting American Dryer Corporation
When contacting ADC, certain information is required to
ensure proper service and parts information. This
information is on the data label, located on the top right
corner of the dryer, viewed from the rear (refer to illustration).
When contacting ADC, please have the model number and
serial number readily accessible.
Information on the Data Label
a. Model Number – The model number is an ADC number,
which describes the size of the dryer and the type of
heat (gas or steam).
b. Serial Number – The serial number allows ADC to
gather information on your particular dryer.
c. Manufacturing Code Number – The manufacturing
code number is a number issued by ADC, which
describes all possible options on your particular
model.
d. Type of Heat – Describes the type of heat; gas (natural
or L.P.), steam or electric.
e. Heat Input (For gas dryers) – Describes the heat input
in British Thermal Units.
f. Electric Service – Describes the electric service for
your particular models.
g. Gas Manifold Pressure – Describe the manifold
pressure as taken at the gas valve pressure tap (refer
to “Using a Manometer”).