ADC AD-78 Clothes Dryer User Manual


 
55
STEAM MODELS ...
1) Low steam supply.
a) Steam trap is too small.
b) Supply line is too small.
2) Low steam pressure.
3) Insufficient make-up air.
4) Lint screen is dirty or is not being cleaned often enough.
5) Restriction in the exhaust.
6) Dirty steam coil ...
a) Fins are clogged with lint.
7) Steam damper system is not functioning properly.
a) Steam damper is sticking closed.
b) Leak in the pneumatic (air) system.
7. Extractors (water) are not functioning properly.
8. Failed microprocessor controller (computer)...temperature calibration is inaccurate.
9. Failed microprocessor temperature sensor... calibration is inaccurate.
10. Failed lint chamber hi-heat switch (thermostat)...opens at incorrect temperature.
11. Microprocessor temperature sensor covered with lint.
NOTE: Lint accumulation on the sensor bracket can act as an insulator which will affect the
accuracy of the Automatic Drying Cycle.
X. At the completion of the "AUTO" drying/cooling cycle, the load is coming out over dried...
1. Percent of dryness (dryness level) of the cycle selected is too high.
2. Factor "A" and Factor "B" is not set correctly or Factor "B" has to be adjusted for adverse local
conditions.
Y. At the completion of the "AUTO" drying/cooling cycle, the load is coming out still damp...
1. Percent of dryness (dryness level) of the cycle selected is too high.