ADC AD-170SE Clothes Dryer User Manual


 
11
CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors. Every 6
months, inspect the exhaust ducting and remove any lint build up.
IMPORTANT: The dryer must be installed in a location/environment, which the ambient
temperature remains between 40° F (4.44° C) and 130° F (54.44° C).
B. UNPACKING/SETTING UP
Remove protective shipping material (i.e., plastic wrap and/or optional shipping box) from dryer.
IMPORTANT: Dryer must be transported and handled in an upright position at ALL times.
The dryer can be moved to its final location while still attached to the skid or with the skid removed. To remove
skid from the dryer, locate and remove the four (4) lag bolts securing the base of the dryer to the wooden skid.
Two (2) are at the rear base, and two (2) are located in the bottom of the lint chamber. To remove the two (2)
lag bolts located in the lint chamber area, remove the lint drawer and the three (3) Phillips head screws securing
the lint door in place.
1. Leveling Dryer
a. To level the dryer, place 4-inch (10.16 cm) square metal shims or other suitable material under the base
pads. It is suggested that the dryer be tilted slightly to the rear (refer to the illustration above).
b. The V-belts are disconnected from the basket (tumbler) drive motor for shipping. Reconnect V-belts
before starting the dryer.