7
CABLE-
ENTRY
PLATE
CABLE CLAMP -
EVERY12”-16”
1. Decide the best location for the cables to enter the
vehicle, and the location of the switch and receiver
(see “Installing the switch and receiver” below.) Drill
a 1/2” hole in the roof, push wires inside. Make
proper connections (remember you must have fil-
tered +12 VDC power source).
2. Place cable-entry plate over hole and cables. Screw
in place. Seal plate and screw holes with approved
sealant (not included).
FIGURE 7
Cable entry installation —
3. Depending on the length of the cable on the roof,
you may need to use cable clamps or wire ties (not
provided) between the unit and your cable-entry plate.
Clamping the cable every 12”-16” should eliminate
any unnecessary cable movement, Figure 7.
Installation • Wiring
INSTALLATION
1. Decide the location of the power on/off switch.
Be sure the switch is turned off before you begin!
See diagram below.
Wall or panel mount: Drill 1-1/4” hole, pull wires
through wall or panel.
Surface mount: Determine location and direction of
box. Mount box feed wire into one of the box open
ings.
Select plate cover (brown or white provided) and snap
the rocker switch into the switch plate. Be sure switch is
off!
2. Connect +12 VDC power from vehicle, using red
spade connector, to isolated spade on switch.
3. Connect red power wire from MV-0500 using red
spade connector to center spade on switch.
4. Connect vehicle ground and black ground wire,
using yellow spade connector, to silver spade on
switch.
FILTERED
+12 VDC
FROM
VEHICLE
INSTALLING THE POWER SWITCH DIAGRAM
STEP 4
STEP 3
STEP 2
TWO BLACK GROUND WIRES
1 FROM VEHICLE
1 FROM MV-0500
ON/OFF ROCKER
WITH LIGHT
(SHOWN IN OFF
POSITION.)
MV-0500
RED POWER
WIRE
FIGURE 8