USING YOUR THERMOSTAT
System Operation
Temporary Temperature Hold
You can temporarily adjust the tem-
perature in your home at any time while
your thermostat is running a program by
touching either
or keys. The dis-
play will indicate “Temporary Hold At”
to the left of the setpoint temperature. To
cancel the temporary setting before the
next period begins, touch Run Schedule
to return to the program.
Example: If you turn up the heat during
the Morning program, it will remain at the
new temperature until the time for the
next program period (Day program).
Touch the SYSTEM key to select the
thermostat operating mode desired.
When the system is calling for first stage
heat or cool, “Low” will display on the
touchscreen. When second stage is re-
quired, the display will show “High”. The
setpoint temperature can be changed by
touching the
or keys.
Auxiliary Heating
Heat Pump Only
The system automatically activates
Auxiliary Heating when the outside tem-
perature is too cold for the heat pump to
efficiently heat the home. When Auxiliary
Heating is called for, the display will show
“Auxiliary Heat”.
Emergency Heating
Heat Pump Only
Heat pump malfunction is rare, but
should it happen, Emergency Heat can
be manually activated by touching the
SYSTEM key to Em. This will start the
electric or fossil fuel system to provide
heat. The display will show “Auxiliary
Heat”.
SETTING UP YOUR THERMOSTAT OPTIONS
The Thermostat has comfort and performance options that can be selected and ad-
justed. These options are in the Thermostat Options Configuration Menu. On the Home
Screen Display, touch the Menu key to display additional key choices.
NOTE:
When in the Thermostat Options Configuration Menu, holding the Installer Config key
for 3 seconds again will change the display to the Advanced Installer Configuration
Menu which is used by your contractor. To exit this menu and return to the Thermostat
Options Configuration Menu, press the Menu key, or press Run Schedule to return to
the Home Screen Display.
Select air filter maintenance re-
minder. Scrolling message will show
“AIR FILTER MAINTENANCE”.
Default is OFF. It can be changed
to a setting from 25 to 1975 hours
in increments of 25 hours to select
the amount of time for the reminder.
Consult your contractors for the hours
and type of filter. Setting of 225 hours
is typically 3 months of run time.
When the system has run for the
selected length of time, the scrolling
message area will show “CHANGE
FILTER” to indicate maintenance is
required.
Select UV lamp maintenance re-
minder. Scrolling message will show
“UV LAMP MAINTENANCE”. Default
is OFF. It can be changed to a setting
from 25 to 1975 days in increments of
25 days to select the amount of time
for the reminder. Setting of 350 days
is an annual reminder.
Based on this setting, the scrolling
message area will show “CHANGE
UV LAMP” to indicate maintenance
is required.
1
2
1
2
USAGE GUIDE
SET-UP