MAINTENANCE
Hot oil and hot parts can cause burns. Use care when operating,
cleaning, and servicing the fryer.
Spilling hot fryer compound can cause severe burns. Do not
move fryer without draining all frying compound from the tank.
FLUE VENT INSPECTION
When the fryer is cool, inspect annually. Check the flue and clear any obstructions.
Service in the US and Canada
Contact you local Vulcan-Hart Service office or address on the front of this manual.
In Australia
Contact Hobart Food Equipment PTY. LTD., 16 Hilly Street Morlake, N.S.W. 2137 Australia;
P.O. Box 100, Concord N.S.W. 2137; Tel: (02) 9736 1200; Fax: (02) 9736 1555.
www.hobartfood.com.au
Troubleshooting Chart:
Problem: Probable Cause:
No Heat: Thermostat dial not turned on.
Pilot not lit.
Gas supply not turned on.
Wire connections loose (call service)
Wires connections need cleaning (call service)
Thermopile (call service)
Insufficient or too much heat: Thermostat dial not set to desired temperature.
High limit tripped (call service)
Temperature probe (call service)
Tank will not drain: Shortening too cold.
Drain pipe clogged with debris.