A SERVICE OF

logo

F35425 (October 2005) Page 12 of 23
ENDURANCE SERIES GAS RANGES - REMOVAL AND REPLACEMENT OF PARTS
4. Inside the oven remove the hex head bolts and
spacers attaching the motor grate to the motor
mounting plate and remove the motor grate.
5. Remove the motor and rotor blower assembly
from inside the oven.
6. Remove the fan from the motor.
7. Remove motor from motor mounting plate.
8. Reverse the procedure to install a new motor.
CONVECTION OVEN SOLENOID
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
WARNING: SHUT OFF THE GAS BEFORE
SERVICING THE UNIT.
WARNING: ALL GAS JOINTS DISTURBED
DURING SERVICING MUST BE CHECKED FOR
LEAKS. CHECK WITH A SOAP AND WATER
SOLUTION (BUBBLES). DO NOT USE AN
OPEN FLAME.
1. Disconnect gas supply to the range.
2. Disconnect the solenoid electrical connectors.
3. Disconnect gas supply lines from both sides of
the solenoid.
4. Remove solenoid mounting screws and
solenoid.
5. Reverse the procedure to install the
replacement solenoid.