![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/4/5d/45d8f821-91a2-4e0d-b9bf-ec7e3ec57eab/45d8f821-91a2-4e0d-b9bf-ec7e3ec57eab-bg86.png)
3 Tests and Diagnostics
3.3 Setting of the hardware configuration
3-10 [CONFIDENTIAL] TECRA M9 Maintenance Manual (960-631))
7. “Create DMIINFO TXT (Y/N) ?” is displayed. Press Y, then the
DMI information (text data) is written to the Floppy disk, etc.
• Setting of the HWSC
• Setting of the UUID
• Display of the DMI information (including UUID)
After completion of the above settings, H/W configuration & DMI
information are appeared in order. Check the contents and press Enter.
Subtest 2 DMI information save
This is one of tools to copy the DMI information to a new PCB after
replacing.
This subtest saves all the DMI data in a floppy disk.
Subtest 3 DMI information recovery
This is one of tools to copy the DMI information to a new PCB after
replacing.
This subtest writes all the DMI data in the floppy disk into the new PCB.
NOTE: Since the data of UUID is updated every time when this subtest, DMI information
recovery, is done, the saved UUID data is not written.
Subtest 4 System configuration display
This subtest displays the information of the system configuration.
When the following message appears, confirm the contents and press Enter.
Press [Enter] key
For more details on the system configuration information, refer to “3.25
System configuration”.
Subtest 5 E2PROM test (MAC/GUID/DMI)
It checks whether the MAC address, GUID of IEEE1394 and DMI
information are written.