![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/b/23/b23af1eb-68fe-45c3-adba-a5e39b7d6ad9/b23af1eb-68fe-45c3-adba-a5e39b7d6ad9-bg4c.png)
14. OPERATING PROCEDURES
14.6 TARE/SAVE FUNCTION PROCEDURES
14-11
14.6 TARE/SAVE FUNCTION PROCEDURES
Menu: REG., M.DOWN, or REWRAP
Mode: WEIGH or FIX (Tare % function is available in WEIGH mode only.)
NOTES: 1. Tare subtraction is available up to 2.000 lb. for the US type, and up to 1.000kg (2.205lb) for the CA/QR type. When
tare subtraction is in operation, however, the scalable range for net weight becomes less by the amount of the tare.
(Net weight-Gross weight-Tare)
2. Preset tare must be a multiple of 2 g for CA/QR type (Kg scale) and a multiple of 0.005 lb for US/CA type (Lb scale).
3. The tare % function is available when the Initial Setting #8-7 is set to 1 (SL-9000) or #28-4 is set to 1 (SL-9000N). The
speed key #70 will function as the % key (Refer to page 5-3). Set a tare % within the range from 0.0 to 99.9.
4. When a commodity is placed on the platter and the calculated tare exceeds the maximum, a “TARE WEIGH OVER”
error will occur.
There aretwo kinds of tare subtraction procedures, one is “Direct tare”, the other is “Preset tare “.
The key is used to save the tare, unit price, and PLU data after taking a commodity from the
platter.
SAVE
0.200 lb
the platter.
(Ex. 0.200 lb)
The PLU data and tare are
saved.
platter.
(Ex. 1.000 lb)
T
1 0 0
SAVE
PLU
on the platter
2 0 0
T
Remove the commodity
together with the container.
C
PLU
T
PLU
0
Remove the Commodity
together with the container.
PRT
C
%
1 0 0
%
1 0 0
%
Tare %
Tare %