MAINS OPERATION & RESULTING TEMPERATURE
MAINS OPERATION & RESULTING TEMPERATURE
The following tables allow determining power supply and cabling requirements.
The power drawn from the mains network is converted into output power to feed the connected
loudspeaker systems and into heat. The difference between power consumption and dispensed power
is called power dissipation (Pd). The amount of heat resulting from power dissipation might remain
inside of a rack-shelf and needs to be diverted using appropriate measures. The following table is
meant as auxiliary means for calculating temperatures inside of a rack-shelf system/cabinet and the
ventilation efforts necessary.
The column „Pd“ lists the leakage power in relation to different operational states. The column „BTU/hr“
lists the dispensed heat amount per hour.
CP 1200
U
mains
[V]
I
mains
[A]
P
mains
[W]
P
out
[W]
Pd
(5)
[W]
BTU/hr
(1)
idle
230V 0,37 42 - 42 143
Max. Output Power @ 8
(1)
230V 4,6 743 2 x 240 263 895
Max. Output Power @ 4
(1)
230V 7,5 1310 2 x 400 510 1740
1/3 Max. Output Power @ 4
(1)
230V 4,7 774 2 x 133 508 1735
1/8 Max. Output Power @ 4
(1)
230V 3,2 496 2 x 50 396 1350
1/8 Max. Output Power @ 4
(2)
230V 3,0 460 2 x 50 360 1230
1/8 Max. Output Power @ 4
(2),(4)
254V 3,4 600 2 x 63 426 1455
Normal Mode (-10dB) @ 4
(1)
230V 3,0 450 2 x 40 370 1260
Rated Output Power (0dB) @ 4
(1)
230V 6,6 1152 2 x 300 552 1885
Alert (Alarm) Mode (-3dB) @ 4
(1)
230V 5,0 828 2 x150 528 1800
Max. Output Power @ 2
(1)
230V 11,6 2210 2 x 600 1010 3445
1/8 Max. Output Power @ 2
(1)
230V 5,0 820 2 x 75 670 2285
1/8 Max. Output Power @ 2
(2)
230V 4.7 755 2 x 75 605 2065
(1) Sine Modulation (1kHz) (2) VDE-Noise (3) 1BTU = 1055.06J = 1055.06Ws
(4) 10% Mains Over Voltage (5) Pd = Leakage Power
The following factors allow direct proportional calculation of the mains current Imain for different mains
supply voltages: 100V = 2.3; 120V = 1.9; 240V = 0.96