UNDERCOUNTER REFRIGERATION
Electrical
The electrical supply should be located within the shaded
area shown in the illustration. For ice machine models, it is
recommended that electrical supply be placed in an adja-
cent cabinet. A separate circuit, servicing only this appli-
ance is required.
IMPORTANT NOTE: For outdoor models UC-24RO and
UC-15I(P)O, a ground fault circuit interrupter (GFCI) is
required to reduce the risk of electrical shock. A GFCI is not
recommended for use with other undercounter models and
may cause interruption of operation.
Installation must comply with all applicable electrical codes.
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp
Receptacle 3-prong grounding-type
3" (76)
15
1
/2"
(394)
2"
(51)
LEFT SIDE
OF OPENING
FLOOR
Electrical supply location.
W
OPENING WIDTH
34
1
/2"
(876)
OPENING
HEIGHT
24" (610)
OPENING
DEPTH
TOP VIEW
SIDE VIEW FRONT VIEW
Opening Dimensions
UNDERCOUNTER MODELS
OPENING WIDTH
MODEL W
UC-24R 24" (610)
UC-24C(I) 24" (610)
UC-24BG 24" (610)
UC-24RO 24" (610)
ICE MACHINE W
UC-15I(P) 15
1
/4" (387)
UC-15I(P)O 15
1
/4" (387)