A SERVICE OF

logo

5-1
STARCommandSpecications
Rev. 0.70
5. APPENDIX
5-1 Status Specications
Thisfunctioniseffectiveonlywhenusinganinterfacecapableofbi-directionaldatacommunications.
Refertoyourprinter’sproductspecicationmanualtoverifyiftheinterfacecableontheprinteryouuseiscapableof
bi-directionaldatacommunications.
5-1-1 ENQ Command Status
This statu s is t he one the printe r tran smits using the E NQ co mmand.
Bit Contents
Status By model
“0” “1”
BD100 SP2000 BD500 SP500 SP700
7 Compulsion SW Open Closed
6
Bufferoverow No error Overow
5
Reception Buffer
Empty
Has Data Empty
4
Fixedat“0” - - - - - -
3 Paper end Paper No paper
2 Mechanical Error No Error Error
1 Framing Error No Error Error
0 Parity Error No Error Error
• Framing error/parity error
These errors occur when using a serial I/F.(For anything other than a serial interface, always Bit 0 = Bit 1 = 0.)
With these errors, the information at that time is held and the error status is sent when there is an inquiry of the status
bythiscommand.
• Compulsion SW
When the conversion switch is ON, Bit 7 = 1.
5-1-2 EOT Command Status
This status is the one the printer transmits using the EOT command.
Bit Contents
Status By model
“0” “1”
BD100 SP2000 BD500 SP500 SP700
7 - - - - -
6 - - - - -
5 - - - - -
4
Fixedat“1” - - - - - -
3 Paper end Paper No paper
2 Paper near-end Paper No paper x x
1
Black mark detection
error
No Error Error x x
0
Fixedat“0” - - - - - -
• Paper end
Same as the ENQ status Bit 3
• Bit 5 to 7 states are unknown