A SERVICE OF

logo

Opticon
OPR 3001
Specifications Manual
34
13. Durability
13.1. Electrical Noise
No malfunction should occur when sinusoidal electrical noise (10Hz -100kHz, < 0.1Vpp)
is added to a power supply line.
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
PCS: 0.9
Resolution: 0.25 mm
Symbology: 9-digit Code-39
Quiet Zone: 10 mm
N/W Ratio: 1:2.5
Distance: 100 mm from the edge of scanner
Angle: α = 0° β = 15° γ = 0°
Curvature: R =
Power Supply Voltage: 6.0 V (RS-232C) / 5.0 V (USB and Wedge)
13.2. Static Electricity
Air discharge: 8 kV max (No malfunction)
15 kV max (No destruction)
Contact discharge: 6 kV
Contact discharge at the hook and the screw
Measurement environment: Use electrostatic testing device compliant with IEC 61000-4-2
Discharge resistance: 330
Capacitor charging: 150 pF