The cover over the Allen key socket must be unscrewed before the Allen
key can be inserted and the Hand Crank operated.
Hand Crank Torque: 6 - 8 Nm ( 2600 N – 6800 N load )
Piston Rod movement per turn
Gear A = 10.5 mm
Gear B = 6.0 mm
Gear C = 4.0 mm
Application hints
The actuator is weather proof for use in outdoor applications. The actuator
can be washed down with a high pressure washer, but it should not be used
under water.
Optionally the actuator is overload protected with a slip clutch. The clutch will
slip when the load exceeds approx. 1.2 - 1.4 times the actuators rating.
The duty cycle at max. load is 20% on time. This means if the actuator
runs continuously for 20 seconds it must remain off for 80 seconds before
operating again.
The manual hand crank can be used in the case of power failure.
Note: The power supply has to be disconnected during manual
operation.