4
GF 300 BV Allagash
Specifications
The Jøtul GF300 BV Allagash is a atmospherically-
vented gas fireplace heater designed only for
vertical venting directly to the outside of the house,
using listed, Type B-vent pipe.
Input Rates
Natural Gas
26,000 BTU/hr. maximum input
15,000 BTU/hr. minimum input
Propane
26,000 BTU/hr. maximum input
13,500 BTU/hr. minimum input
Inlet Pressure: MIN MAX
Natural Gas: 5.0 WC (1.24 kPa) 7.0 WC (1.74 kPa)
Propane: 12.0 WC (2.99 kPa) 14.9 WC (3.71 kPa)
Manifold Pressure: MIN MAX
Natural Gas: 1.2 WC (.30 kPa) 3.8 WC (.95 kPa)
Propane: 2.9 WC (.722 kPa) 11.0 WC (2.74 kPa)
Piezo Ignitor / Standing Pilot
13”
330 mm
Rear Exit
21 5/8 ”
550 mm
Top
ExitFlue
Collar
25”
635 mm
Top Plate
27 3/4”
705 mm
C
L
16 1/2”
420 mm
23”
584 mm
4 1/2”
114 mm
11 1/2”
292 mm
C
L
C
L
Suggested Tools for
Installation and Service
• External regulator (for Propane only)
• Piping which complies with local code
• Manual shutoff valve (T-Handle in Massachusetts)
• Sediment trap - if required by code
• Tee joint
• Pipe wrench
• Pipe sealant
• 10 mm open end wrench
• 1/2”, 7/16” open end wrench or deep socket
• Phillips head screwdriver
• Flat head screwdriver
• 1/4” nut driver
• 4 mm allen wrench
• Gloves
• Safety glasses
• Torx T20 screwdriver
• Leak test solution
• Reciprocating Saw
• Power Drill
27 3/4”
705 mm
22 1/4”
565 mm
THIS FIREPLACE IS SHIPPED FROM THE FACTORY
FOR USE WITH NATURAL GAS ONLY. FOR USE WITH
PROPANE, THE APPLIANCE MUST FIRST BE
CONVERTED USING #155592 FUEL CONVERSION KIT
PROVIDED. CONVERSION SHOULD BE MADE
BEFORE THE APPLIANCE IS INSTALLED. SEE PG. 11.
With Short Legs, reduce height by 2 1/4” ( 51 mm)