WALL SHIELD
Must be 30” wide and
centered
behind the
stove
Must be 1” off the wall
and 1” off the floor.
With standard legs, the
shield must be 32” high.
With optional short legs,
the shield must be 30”
high.
&20%867,% /(
:$//
WALL SHIELD
Must be 1 off the wall
and 1 off the floor.
With standard legs, the
shield must be 40 high.
With optional short legs,
the shield must be 38
high.
Both shields MUST
extend and join in the
corner
The wall shield must extend a
mini mu m of 4 (102mm) past the
ash lip of the stove.
The wall shield must extend a
minimum of 4 (1 02mm) p ast
the side of the stove.
The wall shield must
extend a minimum of
12 (305mm) past the
front corner of the stove.
&20%867,%/(
:
WALL SHIELD
Must be 1 off the wall
and 1 off the floor.
With standard legs, the
shield must be 40 high
With the optional short
legs, the shield must be
38 high.
Both shields must
extend and join in the
corner.
The wall shield must
extend a minimum of 12 (305mm)
past the front corner of the stove.