Page 21 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
controller, the light will
turn on, then back off
with an INSTEON on-level at
a high brightness and an X10
address on-level at a low
Remove the X10 address from INSTEON
controller
Micro module, it takes a
long time for other
INSTEON devices it is
Micro module is trying to
control a responder
responding and may have
been removed
Connect power to the responder
If the INSTEON device is still available,
remove it from Micro module and then re-add it
The load is buzzing when
on or dim.
The dimming component
inside Micro module “chops”
the power line sine wave to
reduce the power
The bulb filaments are vibrating. Use rough-
service, or appliance g
rade bulbs to reduce the
noise
Run Micro module in the “full-on” mode or
switch to a non-dimming Micro On/Off module
Micro module is locked up
A surge or excessive noise
on the power line occurred
Micro module is getting
warm to the touch
It is normal for dimmers to get
warm (Micro module
conforms to safety standards)
Micro module will dissipate about 1 watt per
100 watts of load. Using metal junction boxes,
removing insulation around the outside of the
box and controlling a smaller load will all help
Micro module blinks green
one time after it is
activated
error blink feature. A green
blink indicates that all
responders are
You may disable error blink via software if
desired
Micro module blinks red
one time after it is
activated
error blink to let you know
that a responder did not
acknowledge the command
and that there is a lot of
unacknowledged
communications on the
Confirm that the responder is powered and
available. If you don’t want this device to be a
responder you can unlink it if available or use
software to remove the link. Once the issue is
resolved, you may disable error blink via
software if desired.
Micro module can turn off
my responder
happens when I send an
on
Responder’s scene level is
off
Add responder to scene again at desired
scene on-level
Micro module still controls
devices even after factory
reset
The responder’s link was not
removed prior to Micro
module factory reset (called a
Remove responder from Micro module