Troubleshooting
Problem
Possible Cause
Solution
The LEDs on Micro
module are not turning on
at all
Micro module is not getting
power
Make sure the circuit breaker is turned on
Check junction box wires to ensure all
connections are tight and no bare wires are
exposed
Check the light fixture to ensure all
connections are tight and no bare wires are
exposed
The switch Im replacing
only has two wires
Micro module needs a ne
utral
wire in order to operate
Look in the rear of the junction box for a group
of wires tied together with a wire nut. Those
are commonly neutral wires.
Pull a neutral from nearby junction box
Micro module is not
receiving signals from
INSTEON or X10
controllers
The controller is plugged into
a power strip
Powerline signals can’t travel through some
power filters. Plug controller into wall outlet.
Other modules are
attenuating the signal or
causing noise on the line
Plug other modules into a signal filter or move
the modules or controller to another outlet
INSTEON devices act as network repeaters.
Add new or move existing INSTEON devices
and retest.
Micro module and the
controller are on opposite
powerline phases
Make sure there are at least 2 dual-band
INSTEON products are properly installed to
bridge the phases
The light turned on by
itself
Another controller, a timer, or
stray X10 signals triggered
Micro module
Install a power line signal blocker in your home
to keep X10 signals from neighboring homes
from interfering. Consider not using Micro
module in X10 mode.
Micro module may have an
undesired responder
membership
Use software to remove membership or
perform a factory reset and re-setup Micro
module
The controlled light does
not appear to turn on or
off right away
Responder’s scene ramp rate
might be quite slow
Set a faster ramp rate and relink responder
Micro module responds to
on commands but not off
commands
Load connected to Micro
module is producing electrical
noise that is interfering with
the Micro module
reception of
powerline signal
Install an inline signal filter between the load
and Micro module
Install additional INSTEON devices to boost
the INSTEON signal
I can’t turn Micro module
on (but I can turn it off,
brighten and dim it)
The on-level may be set to
fully-off or very dim
Set a brighter on-level. See Local On-Level
.
When I try to turn on my
Micro module may be set up
Remove the X10 address from Micro module