![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/1/5a/15ac7719-96fd-4f11-abde-a326511b931a/15ac7719-96fd-4f11-abde-a326511b931a-bg41.png)
009
Go to Step 010.
010
(From step 009)
– Observe the Status column on the screen. If the status of any disk drive is ‘Power’,
that disk drive has detected a loss of redundant power or cooling. In the example
shown here, the fourth disk drive has detected such a loss.
On the RSM configurator this is shown as a red line in the Physical View, with the
added text Break.
┌───────────────────────────────────────────────────────────────────────┐
│ISSACFG SSA Configurator and Service Aids yymmdd DOS Version"
└───────────────────────────────────────────────────────────────────────┘
┌────────────────────────────┐
│ Main Menu │
├────────────────────────────┤
│ ┌─────────────────────────────────────┐
│ │ Disk Service Aids │
│ ├─────────────────────────────────────┤
│ │ Link SSA UID Status │
│ │ Port A1 │
│ │ UIDxxxxx │
│ │ UIDyxxxx │
│ │ UID3xxxx │
│ │ UID4xxxx Power │
│ │ Port A2 │
│ │ Port B1 │
│ │ No disks │
└──│ Port B2 │
│ │
│ │
└─────────────────────────────────────┘
┌────────────────────────────────────────────────────────────────┐
│<ESCAPE> Exit <ENTER> Select <F1> Help <F2> Format │
│<F3> Certify <F4> ServiceMode <F5> Diagnostics <F9> FlashOn │
│<F1> FlashOff │
└────────────────────────────────────────────────────────────────┘
DO ONE OR MORE DISK DRIVES HAVE A ‘POWER’ STATUS?
Yes No
011
Go to Step 013 on page 2320-4.
012
Go to the START MAP for the unit in which the disk drive is installed.
MAPs 2320-3