A SERVICE OF

logo

Netfinity EXP300 Type 3531 7
You must use ServeRAID version 4.10 or later for your ServeRAID controller to report
status and alerts properly. To download the latest ServeRAID family software, visit
the following IBM web site at: http://www.ibm.com/pc/support.
For up-to-date information about the IBM Netfinity Manager and Netfinity Director
software support available for your EXP300, visit the following IBM Web site at:
http://www.ibm.com/pc/us/netfinity
For Netfinity Manager users, download Netfinity Manager version 5.20.6 SP1 or later.
For Netfinity Director users, download Netfinity Director, UM Server extensions
version 2.12 SP1.
Symptom-to-FRU index
This index supports Netfinity EXP300 – Type 3531 expansion units.
Use this chart to find solutions to problems that have definite symptoms.
Problem indicator FRU/Action
Amber LED on Drive CRU 1. Failed drive
Refer to “Replacing hot-swap drives” on page 20
Amber LED on ESM board 1. Failed ESM board
Refer to “Replacing an ESM board” on page 24.
Amber LED on front panel 1. Indicates that a Fault LED somewhere on the expansion
unit has been turned on. (Check for amber LEDs and
CRUs.)
Refer to “Rear controls, indicators, and connectors” on page
15
Amber LED on and green LED off 1. Turn on all power supplies
2. Power supply
Amber and green LEDs on 1. Failed power supply
All green LEDs off 1. Check that all expansion unit power cables are plugged
in and the power is on. If applicable, check that the
main circuit breakers for the rack are turned on.
2. Check the main circuit breaker and ac outlet.
If the external switch 1 is set to Off, the SCSI controller
must be cabled to the EXP300 and turned on.
3. Power supply
4. Mid-plane board
Amber LED flashing on Drive CRU 1. Drive rebuild or identity is in process.
Amber LED flashing on power
supply
1. Power supply
Amber LED on and green dc power
LED off on power supply
1. Turn power switch on
2. Power supply