Appendix A - Modb
us Variable Map
404114 - Display Alarms Word 1
Bit Event Type
Event Code
Event Name
1 Deviation
P6C_
Pressure Transducer Missing
others Reserved
404115 - Display Alarms Word 2
Bit Event Type
Event Code
Event Name
12 Alarm
CAG_ Modbus Com
munication
15 Alarm
CAC_ CAN Communication Display
others Reserved
Table 6 Pump Status and Control Bits
404100 -
Pump Status Bits
Bit Meaning
0
Reads 1
ifthepumpistryingtomove
1
Reads 1 if the pump is actually moving
2
Reads 1 if there are any active alarms
3
Read
s 1 if there are any active deviations
4
Reads 1 if there are any active advisories
oth
ers
Reserved for future use
40
4202 - Pump Control Bits
Bit Meaning
0
R
eads 0 for an active alarm or deviation. Reset to 1 to clear.
1
Setto1toresetthebatchtotal
2
Set to 1 to reset the maintenance counter
others
Reserved for future use - only write 0
36 3A2527E