![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/6/06/606e2309-22dc-4ee2-ac39-be04138df42a/606e2309-22dc-4ee2-ac39-be04138df42a-bgf.png)
TP Receivers • Installation and Operation
2-3
N
The following transmitters are compatible with the
TP R 15HD A, TP R BNC A and TP R BNC AV
receivers:
TP T 15HD 45, TP T A 45,
TP T 15HD A, TP T 15HD AV,
TP T 468
N
All TP transmitters include a 15V or 12V external
power supply. The transmitters (with the exception of
the TP T 15HD 45 and TP T A 45) also receive power
from the associated Extron TP receiver(s) (with the
exception of the TP R 15HD A) via the TP cable. Extron
recommends using the local power supply; however, the
power supply may not be necessary in some applications.
Use the following guidelines:
•
The TP T 15HD A and TP T 15HD AV may not
require a local power supply for cable lengths of 300
feet or less.
•
All of the following transmitters require the local
power supply:
TP T BNC DA4
TP T 15HD 45
TP T A 45
VTT001
Any transmitter connected to a TP R 15HD A
If problems are encountered, such as a missing or poor
quality image on the output, use the local power supply.
See Troubleshooting, on page 2‑19 for other indications
that may require using the local power supply.
Adjust the picture controls on the transmitter(s) and the
receiver. See Controls and Indicators in this chapter and
refer to the TP Transmitters Family User’s Manual, part
#68-546-03.