If the instrument does not switch ON or displays the low battery symbol, replace the battery as
follows:
1. Slide off the rear battery compartment cover
2. Replace the 9V battery
3. Secure the battery compartment
4.
You, as the end user, are legally bound (EU Battery ordinance) to return all used
batteries, disposal in the household garbage is prohibited! You can hand over your
used batteries / accumulators at collection points in your community or wherever batteries /
accumulators are sold!
Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the
end of its lifecycle
Maintenance
Always keep the instrument dry
To clean, wipe the meter with a damp cloth. Use a mild detergent if necessary but never use
abrasives or solvents.
Prevent dirt from accumulating at the electrode pins
Specifications
Display Backlit LCD digital display and tri-color LED bargraph scale
Resolution 0.1%
Accuracy Pin mode: ± (5% rdg + 5 digits)
Pinless mode is a relative reading only
Measurement principle Electrical resistance (pins)
Electromagnetic sensor (pinless)
Range 0.0 to 99.9 %Relative (pinless)
6.0 to 94.8 %WME (pins)
Electrode pin length 11mm (0.44”)
Electrode pin type Integrated, replaceable
Power supply 9V alkaline battery
Low Battery Indication Battery symbol displayed on LCD
Meter housing Impact-proof plastic
Operating Temperature 32 to 122
o
F (0 to 50
o
C)
Operating Humidity 80% Relative Humidity maximum
Dimensions 8 x 2.3 x 1.7” (203 x 58 x 43mm)
Weight 7.2 oz (204g)