A SERVICE OF

logo

4
ELECTRICAL DIAGRAM FOR DC MOTOR
5
PUMP CONSTITUENTS
1. Pump & Motor Assembly
2. Nozzle Holder
3. Elbow
4. Suction Tube (2 parts)
5. Bung Nut
6. Hose Assembly (12’ Long x ¾” ID Anti Static Hose)
7. Fuel Control Nozzle
8. Power Cord complete with Fuse & Clamps
9. PTFE Tape
5
4
7
3
8
9
6
ELECTRICAL INSTALLATION - DC MOTORS
1
2
Cable systems and accessories should be installed in positions that prevent them from being subject to mechanical damage, corrosion,
chemical attack, heat and other detrimental environmental conditions. Selection of the wiring system and cable type must consider
these and where exposure to such conditions are avoidable, protective measures such as minimizing the risk of mechanical
damage by the use of appropriate armoured cable types should be considered. Motor must be connected using a cable incorporating an
earthing or equipotential bonding conductor.
Filed wiring shall comply with requirement stated article 501 in National Electrical Code (NEC) for Class I, Division 1 Location.
5
M
+
-
+
-
MOTOR
RED
BLACK
ON / OFF
TOGGLE SWITCH
+
-
RED
BLACK