41
Tools
Time
5 min
1
After opening the control boz, disconnect
the electrical plug connectors
Unscrew the two screwa and remove the
PCB
Tools
Time
5 min
1
Drain boiler (see 3.3). Remove the clip and pull the ow
switch assembly towards you
Twist the ow switch assembly to disengage
C.H. Filter
D.H.W. Flow Switch assembly (E-COMBI)