Zanussi ZDE 57140W Clothes Dryer User Manual


 
26 electrolux installation
safety cut-outs with which the machine
is fitted may operate.
When operating the tumble dryer, the
room temperature must not be lower
than +5°C and higher than +35°C, as it
may affect the performance of the
appliance.
Stacking kit
A special stacking kit is available through
your dealer, to enable the mounting of
the dryer on top of a front loading
washing machine with cover’s depth
between 48 and 60 cm.
Read carefully the instructions supplied
with the kit.
Door reversal
To make it easier to load or unload the
laundry the door can be reversed.
This operation must be carried out by
qualified personnel.
Please contact the nearest Service
Centre.
Electrical connection
Any electrical work required to install this
appliance should be carried out by a
qualified electrician or competent
person.
WARNING: THIS APPLIANCE MUST
BE EARTHED.
The manufacturer declines any
liability should this safety measure
not be observed.
P1107
Before switching on, make sure the
electricity supply voltage is the same as
that indicated on the appliance’s rating
plate. (See picture on page 5).
The appliance is supplied with a 13amp
plug fitted.
In the event of having to change the fuse
in the plug supplied, a 13amp ASTA
approved (BS1362) fuse must be used.
Should the plug need to be replaced for
any reason, proceed as described
below.
The wires in the mains lead are coloured
in accordance with the following code:
Green and Yellow - Earth
Blue - Neutral
Brown - Live
The wire coloured green and yellow
must be connected to the terminal
marked with the letter «E» or by the
earth symbol or coloured green and
yellow.
The wire coloured green and yellow
must be connected to the terminal
marked with the letter «E» or by the
earth symbol or coloured green and
yellow.
GREEN &YELLOW
BROWN
CORD CLAMP
BLUE
13A
P1041
E