Zanussi ZDC46130W Clothes Dryer User Manual


 
16
Something not working
Certain problems are due to lack of simple maintenance or oversights, which can be solved easily
without calling out an engineer. Before contacting your local Service Centre, please carry out the
checks listed below.
During machine operation it is possible that the red Start/Pause pilot light flashes to indicate that the
machine is not working.
Once the problem has been eliminated, press the Start/Pause button to restart the programme. If
after all checks, the problem persists, contact your local Service Centre.
Malfunction Possible cause Solution
Dryer does not work.
Mains plug is not plugged in or fuse
is not working correctly.
Loading door is open.
Have you pressed the START/
PAUSE button?
Plug in at mains socket. Check fuse
in fuse box (domestic installation).
Close loading door.
Press the START/PAUSE button
again.
Drying results
unsatisfactory.
Wrong programme selected.
Lint filter clogged.
Heat exchanger clogged with lint.
Incorrect volume of laundry.
Ventilation slots in base area covered up.
Residue on inside surface of
drum or drum ribs.
Conductance of water at installation
site differs from
standard setting of machine.
Select a different programme the next
time you dry.
Clean lint filter.
Clean heat exchanger.
Observe recommended loading
volumes.
Uncover ventilation slots in base area.
Clean inside surface of drum and
drum ribs
Re-programme standard setting for
degree of drying.
Loading door does not
close.
Fine strainer not in place and/or large
mesh filter not locked in place.
Install fine strainer and/or snap large
mesh filter into place.
125986546.qxp 2008-01-23 10:33 Page 16