14
Adjusting the level of conductivity
Water contains, a variable quantity of limestone and
mineral salts of which quantities vary according to
geographical locations thus varying its conductivity
values.
Relevant variations of the conductivity of the water
compared to those prefixed by the factory could
slightly influence the residual humidity of the
laundry at the end of the cycle.
Your dryer allows you to regulate the sensitivity of
the drying sensor based on conductivity values of the
water by using the following procedure.
To access adjustment mode:
Turn the programme selector dial to switch on the
appliance. In selection mode, press simultaneously
the buttons 1 and 3.
Press the buttons down until the pilot lights above
each ones begin to flash and one of the pilot lights
indicating the drying phase lights , cooling
,
or
end cycle remains lit.
2
3
4
1
Adjusting the level of conductivity:
Press the START/PAUSE button sequentially:
the level of conductivity is indicated by the phase
pilot lights, which light in various combinations as
follows:
Normally, the appliance is factory-set to the highest
level; however, certain models may be configured
differently.
Memorizing the new setting:
Simultaneously press the buttons 1 and 3.
Press the buttons down until the pilot lights above
each ones stop flashing and the buzzer sounds.
LED lit Conductivity
Approximate value
µS/cm
Low < 300
Medium 300 - 600
High > 600
125981701.qxp 4/1/2006 9:27 AM Page 14