Washer Dimensions
Minimum installation spacing for custom undercounter
installation
The dimensions shown are for the minimum spacing allowed.
Custom undercounter installation - Washer only
Minimum installation spacing for recessed or closet
installation, with or without a pedestal
The dimensions shown are for the minimum spacing allowed.
Recessed area or closet installation
Recessed or closet installation - Washer on pedestal
Minimum installation spacing for cabinet installation
The dimensions shown are for the minimum spacing allowed.
For cabinet installation, with a door, the minimum ventilation
openings in the top are required.
Drain System
The washer can be installed using the standpipe drain system
(floor or wall), the laundry tub drain system, or the floor drain
system. Select the drain hose installation method you need. (See
Alternate Parts.)
Standpipe drain system - wall or floor (view 1 & 2)
The standpipe drain requires a minimum diameter standpipe of 2
in. (5 cm). The minimum carry-away capacity can be no less than
17 gal. (64 L) per minute.
1. Side view - closet or confined area
2. Closet door with vents
27"
(68.6 cm)
50¹₂"
(128.3 cm)
38"
(96.5 cm)
31¹₂"
(80.0 cm)
"
"
"
""
96.52
68.6
"
"
"
"
"
"
"
1
1
2
/
1
"
34
(
86.4
cm)
1
2
2.5
(7.6 cm)
(7.6 cm)
1. Recessed area
2. Side view - closet or confined area
7" (17.8 cm)
9"
(22.9 cm)
7" (17.8 cm)
0"
(0 cm)
31¹₂"
(80.0 cm)
27"
(68.6 cm)
0"
(0 cm)
0"
(0 cm)
0"
(0 cm)
30" min.
(76.2 cm)
1
2