10
4. Connect remaining wires
Connect remaining wires to outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover
into slot of dryer rear panel. Secure cover with hold-down
screw. Now, go to “Venting Requirements”.
3-WIRE POWER SUPPLY CORD
CONNECTION
3-wire receptacle (NEMA
type 14-30R)
3-prong plug
Spade terminals with
upturned ends
Ring terminals
Use where local codes permit connecting
cabinet-ground conductor to neutral wire.
1. Remove center screw
B
Remove center terminal block screw (B).
3. Connect remaining wires
2. Connect neutral wire
C
B
Connect remaining wires to outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover
into slot of dryer rear panel. Secure cover with hold-down
screw. Now, go to “Venting Requirements”.
Connect neutral wire (white or center) (C) of power supply cord
to center terminal block screw (B). Tighten screw.
Direct Wire