Recessed area or closet installation
The dimensions shown are for the recommended spacing
allowed (A and B), except the closet door ventilation openings.
The dimensions shown for the closet door ventilation openings
(C) are the minimum required.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances may be required for wall, door and floor
moldings.
Additional spacing of 2.5 cm (1") on all sides of the washer is
recommended to reduce noise transfer.
If a closet door is installed, the minimum air openings in the
top and bottom of the door are required (C). Louvered doors
with air openings in the top and bottom are acceptable.
Companion appliance spacing should also be considered.
Drain System
The washer can be installed using the standpipe drain system
(floor or wall), the laundry tub drain system, or the floor drain
system. Select the drain hose installation method you need. See
“Tools and Parts.”
Standpipe drain system - wall or floor (views A & B)
The standpipe drain requires a minimum diameter standpipe of
5 cm (2"). The minimum carry-away capacity can be no less than
64 L (17 gal.) per minute. A 3.2 cm (1
¹⁄₄
") diameter to 2.5 cm (1")
diameter standpipe adapter kit is provided.
The top of the standpipe must be at least 99 cm (39") high and no
higher than 244 cm (96") from the bottom of the washer.
Laundry tub drain system (view C)
The laundry tub needs a minimum 76 L (20 gal.) capacity. The top
of the laundry tub must be at least 99 cm (39") above the floor
and no higher than 244 cm (96") from the bottom of the washer.
Floor drain system (view D)
The floor drain system requires a siphon break that may be
purchased separately. See “Tools and Parts.”
The siphon break must be a minimum of 71 cm (28") from the
bottom of the washer. Additional hoses might be needed.
Electrical Requirements
A 220 volt, 60 Hz., AC only, 8- or 10-amp, fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is recommended that a separate circuit
serving only this appliance be provided.
This washer is equipped with a power supply cord having an
earthing plug.
To minimize possible shock hazard, the cord must be
plugged into a mating, earthing-type outlet, earthed in
accordance with local codes and ordinances. If a mating
outlet is not available, it is the personal responsibility and
obligation of the customer to have the properly earthed outlet
installed by a qualified electrician.
If codes permit and a separate earth wire is used, it is
recommended that a qualified electrician determine that the
earth path is adequate.
A. Front view
B. Side view
C. Closet door with vents
A
B
C
48.3 cm
(19")
0 cm
(0")
0 cm
(0")
68.6 cm
(27")
2.5 cm
(1")
64.8 cm
(25
¹⁄₂")
10.2 cm
(4")
35.6 cm
(14" max.)
7.6 cm
(3")
7.6 cm
(3")
155 cm
(24 in. )
2
2
310 cm
(48 in. )
2
2
A
B
99 cm
(39")
C
D
99 cm
(39")
71 cm
(28")
WARNING
Electrical Shock Hazard
Electrically earth this appliance.
Do not use an extension cord or an electrical portable
outlet device.
Failure to follow these instructions can result in death,
fire, or electrical shock.