Whirlpool FRONT-LOADING GAS DRYER Clothes Dryer User Manual


 
10
Plan Vent System
Choose your exhaust installation type
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer.
Other installations are possible.
Optional exhaust installations
This dryer can be converted to exhaust out the right side, left side
or through the bottom. If you prefer, you may contact your local
dealer to have the dryer converted.
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for
your installation. Two close-clearance installations are shown.
Refer to the manufacturers instructions.
NOTE: The following kits for close clearance alternate
installations are available for purchase. Please see the
Assistance or Service section of this manual to order.
Over-the-Top Installation:
Part Number 4396028
Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 4396037 - 0" (0 cm) to 18" (45.72 cm)
mismatch
Part Number 4396011 - 18" (45.72 cm) to 29" (73.66 cm)
mismatch
Part Number 4396014 - 29" (73.66 cm) to 50" (127 cm)
mismatch
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
A.Dryer
B.Elbow
C.Wall
D.Exhaust hood
E.Clamps
F. Rigid metal or flexible metal vent
G.Vent length necessary to connect
elbows
H.Exhaust outlet
A.Standard rear offset exhaust installation
B.Left or right side exhaust installation
C.Bottom exhaust installation
H
G
F
E
D
C
A
B
WARNING
Fire Hazard
Cover unused exhaust holes with one of the
following kits:
279818 (white)
280028 (meteorite)
Contact your local dealer.
Failure to follow these instructions can result in death,
fire, electrical shock, or serious injury.
A
B
C
A.Over-the-top installation (also available with one
offset elbow)
B.Periscope installation
AB