The angled hood style (shown following) is acceptable.
See the exhaust vent length chart that matches your hood type
for the maximum vent lengths you can use.
Exhaust systems longer than specified will:
Shorten the life of the dryer.
Reduce performance, resulting in longer drying times and
increased energy usage.
3. Determine the number of elbows you will need.
IMPORTANT: Do not use vent runs longer than specified in the
Vent Length Chart.
In the column listing the type of metal vent you are using (rigid
metal or flexible metal), find the maximum length of metal vent on
the same line as the number of elbows.
Install Vent System
1. (Optional) Put on safety glasses and gloves.
2. Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
3. Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4 in. (10.2 cm)
clamp.
4. Run vent to dryer location. Use the straightest path possible.
See Determine Vent Length. Avoid 90º turns. Use duct tape
to seal all joints.
Install Leveling Legs
1. To protect the floor, use a large flat piece of cardboard from
the dryer carton. Place cardboard under the entire back edge
of the dryer. See illustration.
2. Firmly grasp the body of the dryer (not the console panel).
Gently lay the dryer on the cardboard.
3. Start to screw the legs into the holes by hand. Use a wrench
to finish turning the legs. They should stick out about 1 in.
(2.5 cm).
4. Place a carton corner post under each of the 2 dryer back
corners. Stand the dryer up. Slide the dryer on the corner
posts until it is close to its final position. Leave enough room
to connect the exhaust vent.
Number of
90º turns
or elbows
Type of
vent
Box or
louvered
hoods
Angled
hoods
0 Rigid metal
Flexible metal
36 ft (11 m)
28 ft (8.5 m)
26 ft (7.9 m)
22 ft (6.7 m)
1 Rigid metal
Flexible metal
26 ft (7.9 m)
18 ft (5.5 m)
16 ft (4.9 m)
12 ft (3.7 m)
2 Rigid metal
Flexible metal
16 ft (4.9 m)
8 ft (2.8 m)
6 ft (1.8 m)
2 ft (0.6 m)
4"
(10.2 cm)
2.5"
(6.4 cm)
WARNING
Excessive Weight Hazard
Use two or more people to move and install
dryer.
Failure to do so can result in back or other injury.