Whirlpool BYCD3722W0 Clothes Dryer User Manual


 
CHECKINGYOURVENT
Your dryer must be properly installed and vented to achieve maximum drying efficiency and
shorten drying times. Use the minimum recommended installation clearances (found in your
Installation Instructions) to avoid blocking the flow of combustion and ventilation air. Install your
dryer in a well-ventilated room where the temperature is always above 45°F (7°C). Also make sure
that your dryer is leveled. Refer to your Installation Instructions for more information.
VENIINC
2. Use a 4-inch exhaust hood. Smaller hoods
increase drying times.
f
f
A
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can
result in death or fire.
3. The exhaust vent can be routed up, down, left,
right, or straight out the
back of the dryer. Space
requirements are listed
If the dryer is not properly installed and vented, it
will not be covered under the warranty.
NOTE:
Service calls caused by improper venting
will be paid for by the customer, whether it was a
paid installation or self-installed. For paid installa-
tion, call the company that installed the vent for
adjustment.
in your Installation
Instructions.
or flexible metal foil vent.
Use 4-inch heavy metal
or flexible metal vent.
Do not kink or crush
flexible metal vent. It
must be completely
extended to allow
adequate exhaust air
to flow. Check vent
after installation. Refer
to your Installation
Instructions for proper
length requirements of vent.
6