This document is only intended for qualified technicians who are aware of the respective safety regulations.
Revised on 07/01/2003 Subject to modification
Document No. WOI/WM/2003/001
soaking time is 32 minutes with the machine agitating for the first 2 minutes. This is followed by 20 seconds agitation and
3 minutes soak cycle for the remaining 30 minutes.
*ERROR SIGNALS:
During operation, if any malfunction or misoperation occurs, the timer automatically indicates the same to he user through
an appropriate error signal. The various possible errors during operation and the type of error signal along with the
remedies are listed in the table as below
CAUSE SIGNAL TYPE FREQUENCY REMEDY
Lid is open during the spin
1”BEEP 1” OFF EVERY 5 SECONDS CLOSE THE LID
Improper drain /High drain
time
½”BEEP ½”OFF
½”BEEP 3 ½” OFF
EVERY 5 SECONDS
TILL THE PR. SWITCH
RESETS
REMOVE DRAIN
RESTRICTIONS
Course select button is
pressed down whenever
speedy program is selected
1”BEEP 1”OFF 1”BEEP
1”OFF 1”BEEP 1”OFF
FOR EVRY PRESS OF
COURSE SELECT KEY
NO OPTIONS
AVAILABLE IN
SPEEDY PROGRAM
DYMANIC SOAK
Whenever the user SOAK the wash cycle during this soaking period the machine as alternatively stirs (agitates) for some
time and soaks for some time. This aids better mixing of detergent in water hereby aiding dirt removal. The total soaking
time is 32 minutes with the machine agitating for the first two minutes. This is followed by 20 seconds agitation and 3
minutes soak cycle for the reaming 30 minutes.
SERVICE/DEMO ROUTINE :
To enable the CSE s in the field to test the device for its normal operations, a service routine is provided in these ET
models. to activate this, switch on the machine and press all the feather touch buttons i.e., course select, program select,
start/pause key and the cancel key simultaneously. Then release the cancel button. This will lead the machine o service
routine wherein the following operations are performed in sequence
1. All the 8 LED’s will be lighted.
2. Valve inlet will be switched on for 10 seconds.
3. Normal Agitation for 40 Sec.
4. Slow Agitation for 40 Sec.
5. Drain will be on for 20 Sec.
6. Spin will be on for 8 seconds.
7. EOC Buzzer will be for 15 seconds.