4
INSTALLATION
INSTRUCTIONS
Tools and Parts
Tools needed
Check that you have everything necessary for correct installation.
Proper installation is your responsibility.
Parts supplied
Remove parts package from the dryer drum. Check that all parts
listed are included.
Parts needed
Check local codes, existing electrical supply and venting, and
see “Venting Requirements” and “Electrical Requirements”
before purchasing parts.
Permanent installations require
For ordering information, please reference the “Assistance or
Service” section of this manual. You can also contact the dealer
from whom you purchased your dryer.
Location Requirements
You will need
■ A location that allows for proper exhaust installation. See
“Venting Requirements.”
■ A 120-volt, 60-hz., AC-only, 15 or 20-amo circuit.
■ A grounded electrical outlet located within 2 ft (61 cm) of
either side of the dryer. See “Electrical Requirements.”
■ A sturdy floor to support the dryer weight (dryer and load) of
115 lbs (52 kg). The combined weight of a companion
appliance should also be considered.
■ A level floor with a maximum slope of 1 in. (2.5 cm) under
entire dryer.
Do not operate your dryer at temperatures below 45ºF (7ºC). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
Install the dryer where it is protected from water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
Installation Clearances
Location must be large enough to fully open dryer door.
Dryer Dimensions
†Height with caster is 32½" (82.6 cm)
*Most installations require a minimum 5½ in. (14.0 cm) clearance
behind the dryer for the exhaust vent with elbows. See “Venting
Requirements.”
Minimum installation spacing for recessed area and closet
installation
The following dimensions shown are for the minimum spacing
allowed when the unit is to be operated with, or without, the
Stack Stand Kit. To purchase a Stack Stand Kit, see “Assistance
or Service.”
■ Additional spacing should be considered for ease of
installation and servicing.
■ Additional clearances might be required for wall, door, and
floor moldings.
■ Additional spacing of 1 in. (2.5 cm) on all sides of the dryer is
recommended to reduce noise transfer.
■ For closet installation with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
■ Companion appliance spacing should also be considered.
■ Flat-bladed screwdriver
■ Level
■ Adjustable wrench
■ Gloves (optional)
■ Safety glasses (optional)
■ Duct tape
■ Caulking gun and
compound (for installing
new exhaust vent)
■ Tin snips (new vent
installations)
■ 1 - Cycle Control (timer)
knob
■ 1 - Push to Start button
■ 4 - casters
■ 2 - cord brackets
■ 2 - screws
■ 4 - dryer feet
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the
floor for a garage installation.
Failure to do so can result in death, explosion,
or fire.
23
7
8
(60.6 cm)
"
20
3
4
(52.7 cm)
"
31"
†
(78.7 cm)
*