Whirlpool 240-VOLT ELECTRIC DRYER Clothes Dryer User Manual


 
12
Vent Length Chart
Install Vent System
1. Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
2. Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.
3. Run vent to dryer location. Use the straightest path possible.
See Determine vent length. Avoid 90º turns. Use clamps to
seal all joints. Do not use duct tape, screws or other fastening
devices that extend into the interior of the vent to secure
vent.
Level Dryer
Check the levelness of the dryer. Check levelness first
side to side, then front to back.
If the dryer is not level, prop up the dryer using a wood block.
Use a wrench to adjust the legs up or down and check again for
levelness.
NOTE: It might be necessary to level the dryer again after it has
been moved into its final position.
Connect Vent
1. Using the coupling supplied with the dryer, connect the
exhaust vent to the coupling and secure with a 4" (10.2 cm)
vent clamp. See Illustration below.
If connecting to existing vent, make sure the vent is clean.
2. Turn the coupling and exhaust vent assembly
counterclockwise in the exhaust hole on the back of the
dryer.
3. Make sure the exhaust vent is placed inside the exhaust hood
and then secured to the exhaust hood with a 4" (10.2 cm)
vent clamp.
4. Move dryer into final position. Do not crush or kink vent.
Make sure dryer is level.
Complete Installation
1. Check to be sure all parts are now installed. If there is an
extra part, go back through the steps to see which step was
skipped.
2. Check to be sure you have all of your tools.
3. Dispose of/recycle all packaging materials.
4. Check the dryers final location. Be sure the vent is not
crushed or kinked.
5. Check to be sure the dryer is level. See Level Dryer.
6. Plug into a grounded outlet. Turn on power.
7. Remove the clear protective film on the front edge and any
tape remaining on the dryer.
8. Read Dryer Use.
9. Wipe the dryer drum interior thoroughly with a damp cloth to
remove any dust.
10. Set the dryer on a full heat cycle (not an air cycle) for
20 minutes and start the dryer.
If the dryer will not start, check the following:
Controls are set in a running or On position.
Start button has been pushed firmly.
Dryer is plugged into a grounded outlet.
Electrical supply is connected.
House fuse is intact and tight, or circuit breaker has not
tripped.
Dryer door is closed.
11. When the dryer has been running for 5 minutes, open the
dryer door and feel for heat.
If you do not feel heat, turn off the dryer and check the
following:
There may be 2 fuses or circuit breakers for the dryer. Check
to make sure both fuses are intact and tight, or that both
circuit breakers have not tripped. If there is still no heat,
contact a qualified technician.
NOTE: You may notice a burning odor when the dryer is first
heated. This odor is common when the heating element is first
used. The odor will go away.
Number of
90º turns
or elbows
Type of vent Box or
louvered
hoods
Angled
hoods
0 Rigid metal
Flexible metal
90 ft (27.4 m)
64 ft (19.5 m)
80 ft (24.4 m)
58 ft (17.7 m)
1 Rigid metal
Flexible metal
80 ft (24.4 m)
58 ft (17.7 m)
70 ft (21.3 m)
52 ft (15.8 m)
2 Rigid metal
Flexible metal
70 ft (21.3 m)
50 ft (15.2 m)
60 ft (18.3 m)
42 ft (12.8 m)
A. Coupling
B. Vent clamp
C. Vent coupler
D. Vent clamp
E. Rigid or flexible metal vent
A
B
CD
E
WARNING
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.